SHT-2000 Temperature humidity controller 110V/230V buy and manual guide

In this article you will read a review of a SHT-2000 combined temperature controller with a humidity controller that can control both humidity and temperature at the same time ,can see and  download manual ,wiring conections and more useful info.

Here are the pros and cons of SHT-2000 temperature humidity controller:

Here is pros

  • Red/Blue Color  display
  • If you need upgrade controller has same dimensions as  temperature controller MH1210W or MH13001
  • Two independent relays (one for temperature and one for humidity)
  • Good price – the price is cheaper than you would buy two devices separately
  • Stable and accurate temperature and humidity measurement

Here is cons

  • Possibly setting the target values for the first time will be difficult
  • Range is smaller (-20°C +60°C) but for a hatchery or a drying room is stil OK.
  • Temperature reacts slower than humidity

Review conclusion for SHT-2000 controller:

SHT21 temperature and humidity probe for SHT2000 controller

First, I start with negative features The thermostat responds more slowly than the 1210W model or other NTC 10K probe.this is caused by the SHT21 Probe temperature sensor is inside the plastic sensor and it takes some time until the temperature changes. Control range is  smaler comparison with 1210w temperature controler. Setup is also difirent no have menus – HC ,P7,HS,LS, temperature and humidity settings are the same as XY-WTH1 .

Positive qualities  for SHT 2000 are color-coded temperature humidity on display,Precise Moisture Measurement after stabilization, the temperature is accurate.

 

Manual SHT 2000 temperature controller

Complete video manual with setings for humidifing/dehumidifing – heating/cooling and Calibration:

Wirring diagram manual :

Schemati diagram directly on controller

Setting method: Start value <stop value (program automatically determines working mode is heating/humidifying mode)

Heating/cooling mode setting

Setting mode: setting (starting temperature): Press and hold the ▲ button to start the temperature flashing. Use ▲▼ key to set the starting temperature value.

Setting (stop temperature): Press and hold the ▼ button to stop the temperature flashing. Use ▲▼ to set the stop temperature value.
Heating use case: control the water heater, heat to 65 ° C to stop, the temperature drops back to 50 ° C and start heating again

The first step: heating mode, starting temperature <stop temperature
Step 2: Press and hold the ▲ button to start the temperature flashing. Use ▲▼ to set the starting temperature to 50 °C.
Step 3: Press and hold the ▼ button to stop the temperature flashing. Set the stop temperature to 65 °C with ▲▼ keys, and the setting is completed!
Refrigeration use case: use in the farm, the fan is ventilated to 26 ° C to stop, the temperature is raised to 30 ° C and the ventilation is started again.
Step 2: Press and hold the ▲ button to start the temperature flashing. Use ▲▼ to set the starting temperature to 30 °C.
The third step: long press the ▼ button to stop the temperature flashing, set the stop temperature to 26 °C by ▲▼, the setting is completed!
Humidification/Dehumidification Mode Settings:
Setting (start humidity): Press and hold △ key to start the humidity value flashing. Set the humidity value by △ ▽ key. Set [Stop Humidity]: Press and hold △ key to stop the humidity value flashing, and set the humidity to stop by △ ▽ key value.
Humidification
example: fresh supermarket humidification, control humidifier 50% RH began to humidify, humidified to 80% RH to stop humidification. Setup steps:
Step 1: Press and hold the △ button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 50% RH.

Step 2: Press and hold the ▽ button for 3 seconds to stop the humidity value flashing. Set the value to 80% RH. After the setting is completed, the button will be operated for 5 seconds without returning to the normal display state.
Dehumidification
example: workshop control exhaust dehumidification system, humidity 70% RH starts dehumidification, humidity 40% RH stops dehumidification
Setup steps:

Step 1: Press and hold the △ button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 40% RH.
Step 2: Press and hold the ▽ button for 3 seconds to stop the humidity value flashing, set the value to 70% RH, the setting is completed, the button does not operate for 5 seconds, and automatically returns to the normal display state.

Technical Parameters:

  • Supply power : AC 110-230V
  • Relay control output: 10A (1xtemperature 1x humidity)
  • Humidity control range: 0-100%
  • Temperature control range: -20°C +60°C
  • Acurracy: +-0.3°C and +-3%
  • Dimensions:75x85x35mm

 

 
Package include:
1x AC 110~230V 10A SHT2000 Temperature and Humidity Controller

1x Controller Meter SHT21 Probe

1x Manual

15 thoughts on “SHT-2000 Temperature humidity controller 110V/230V buy and manual guide”

  1. Hello sir, I am from India. I am creating an incubator for 60 to 120 eggs capacity by myself using video on sht2000 digital hygrometer. I got information on how to connect wiring of heating system and humidifier device. I require an information on how to connect wiring for 12v Dc fan for circulation of air in the box-incubator. Please help me or share any video on this.

    Thanks and regards
    Senthilkumar

    1. Relay switch output is as switch simmilar … he make only on off circuit.. connect plus wire to relay “one” terminal , from realy “two” terminal connect to fan (+ pole) , minus pole from fan conect directly to – minus pole

    1. Hi nik wirring STC3008 is very simmlar as AC 230V version , not depend on polarity this is good, can you tell what you build ?

  2. My SHT2000 controller has been working well however my temperature reading Changed to “LLL”. What does this mean and how can it be corrected?

Leave a Reply